Coating thickness can affect corrosion protection, appearance and the clearance of a moving part. A quotation that says “plated” without stating the coating system or measurement requirement leaves too much open. For small hooks, rings and buckles, the buyer should define what is to be measured, where it is to be measured and how results will be accepted.
State the whole coating system
Identify the base material, plating or coating layers, supplementary treatment, appearance and any relevant performance requirement. If the part includes a swivel, spring or gate, ask whether the finish could affect movement. A nominal thickness on a flat test panel may not represent every recessed or high-current-density area of a complex fitting.
The drawing or specification should identify measurement locations that are accessible and meaningful. A critical contact surface may deserve a separate limit from a hidden nonfunctional surface. Agree on the number of readings and whether the requirement is a minimum, range or average before production begins.
Choose a method that matches the substrate
ASTM B499 describes a magnetic method for nonmagnetic coatings on magnetic base metals. Its scope cautions that it is not the method for electrodeposited nickel on steel. ASTM B568 covers X-ray spectrometry for coating thickness and can be useful for coating-and-substrate combinations that other methods do not easily measure. Instrument calibration and part geometry still matter.
A supplier and buyer should therefore agree on the actual method for the actual coating. Do not place a method name in the RFQ solely because it appears on a generic inspection template.
Thickness is not the only acceptance test
An adequate reading does not prove adhesion or service performance. ASTM B571 addresses qualitative adhesion testing of metallic coatings and notes that the appropriate test depends on end use and subsequent fabrication. Corrosion evaluation, appearance and functional movement may also be necessary depending on the product.
Keep a record of the method, calibration status, measurement points, lot identification and results. If the coating supplier changes a process, compare the new finish with the approved sample before assuming equivalence.
For a broader checklist of finish and inspection fields, use the Metal Hardware Buyer Guides. A useful RFQ line is: “State the coating stack, measurable location, method and lot-level evidence you can provide.”
Sources: ASTM B499 magnetic thickness method; ASTM B568 X-ray method; ASTM B571 adhesion testing.